Are your radiators warming up nicely but your running water is staying cold? This is one of the most common combi boiler complaints we get called to across London, and it is actually a useful symptom. If the radiators are heating but every hot tap is cold, the fault is usually somewhere on the domestic hot water side of the boiler.

Better still, several of the causes cost nothing to check. Work through the list below before you book anyone.

Why heating can work when hot water doesn’t

On many combi boilers, opening a hot tap triggers a flow sensor and the boiler switches into hot water mode. A diverter valve and plate heat exchanger are commonly involved in directing that heat to your taps. When your taps run cold but the radiators stay warm, something in your boiler isn’t working or a setting is incorrectly stopping your boiler from functioning properly.

Free checks before you call anyone

  1. Try every hot tap in the home. If only one tap runs cold, the problem is that tap or its mixer cartridge, not the boiler. If they are all cold, carry on.
  2. Check the boiler controls and display. Make sure the hot water temperature hasn’t been turned right down and check for an error code. Some combi boilers also have an eco, warm-start or preheat setting. Turning preheat off can mean hot water takes longer to reach the tap, but it should not normally leave you with no hot water at all.
  3. Look at the pressure gauge. A cold system commonly reads between 1 and 1.5 bar. Very low pressure can stop the boiler serving hot water even while it heats your house. If your boiler instructions allow you to repressurise it yourself, follow the manufacturer’s instructions to top up through the filling loop and close both valves firmly afterwards.
  4. Reset the boiler once. Hold the reset button for a few seconds and let it restart (one reset is fine). If the taps are still cold afterwards, stop there. Repeated resets fix nothing and can mask the real fault.

Common internal causes when the heating still works

A sticking diverter valve is one possibility. On boilers that use one, the valve directs heat between the central heating and domestic hot water circuits. If it fails to move correctly, you can end up with working radiators but poor or no hot water.

A scaled-up plate heat exchanger is also worth considering. As Thames Water’s own hardness data shows, London is a hard-water area, and over time limescale can build up in the components in your taps and boiler (such as the heat exchanger). The effects are gradual: water that gets cooler over weeks, fluctuates between warm and cold or flows more weakly than it used to. An engineer can descale or replace the exchanger, and treating the system afterwards slows the scale returning.

When to call a Gas Safe engineer

If you’ve worked through the basic checks and all taps are still running cold, the fault is likely to be internal to the boiler. Common issues include sticking diverter valves, blocked plate heat exchangers and faulty flow sensors or other control faults. Diagnosing or replacing components inside the boiler isn’t a DIY job. Use a suitably qualified Gas Safe registered engineer.

Plumus repairs combi boilers across London 24/7, our engineers carry or can quickly source the necessary boiler components (such as diverter valves and plate heat exchangers) for the common brands and repairs come with a 12 month guarantee. If limescale has contributed to a boiler issue, ask the engineer whether additional protection would be worthwhile for your property. Annual boiler servicing is the most proactive way to detect developing faults before they turn into breakdowns. Call 020 7126 7126 and we will confirm clear rates before anyone is dispatched.


No hot water FAQs

Why do I only get hot water when the heating is on?

A sticking diverter valve is one common cause, particularly if the hot water behaves differently depending on whether the heating is running. An engineer will need to test the boiler to confirm it.

Why does my hot water keep going cold and then hot again?

Fluctuating water temperature usually points to a scaled plate heat exchanger or a sticking diverter valve. In hard water areas like London, limescale build-up is worth inspecting (especially in the plate heat exchanger).

How do I know it is the boiler and not the water supply?

Run a cold tap. If cold water flows normally, your supply is fine and the fault is on the hot side. If the cold taps are also weak or dry, check with your water company before blaming the boiler.

Can I replace a diverter valve myself?

No. Diagnosing or replacing components inside the boiler isn’t a DIY job, so use a suitably qualified Gas Safe registered engineer. A worn valve can sometimes be repaired with a new diaphragm rather than a full replacement, which an engineer can judge on inspection.